MP801 Air-Quality Gas Sensor
For harmful gas detection, automatic exhaust device
Applications :
*household and office for harmful gas detection
*automatic exhaust device
*air cleaner
Product Advantages:
- *High sensitivity to benzene,toluene,alcohol, smoke
- *Quick response and resume
- *Low power consumption
- *Simple detection circuit
- *Good stability and long life
Product Description:
MP801 gas sensor is for air quality. It adopts multilayer thick film manufacturing technology. The heater and metal oxide semiconductor material on the ceramic substrate of subminiature Al2O3 are fetched out by electrode down-lead, encapsulated in metal socket and cap. Conductivity of the sensor is affected by the concentration of target gas. The higher the concentration is, the higher conductivity of sensor gets. Users can adopt simple circuit to convert variation of conductivity into output signal corresponding to gas concentration.
Technical Parameters:
Model | MP801 | ||
Sensor Type | Semiconductor flat surfaced sensor | ||
Standard Encapsulation | Metal Cap | ||
Detection Gas | benzene,toluene,methanal,alcohol, smoke | ||
Detection range | 0.5~1000ppm(alcohol) | ||
Standard circuit | Loop voltage | Vc | ≤24V DC |
Heating voltage | VH | 5.0V±0.1V AC or DC | |
Load resistance | RL | Adjustable | |
sensor features in standard test condition | Heating resistance | RH | 95Ω±10Ω(Room Temp.) |
Heating consumption | PH | ≤300mW | |
Surface resistance | RS | 1KΩ~15KΩ(in 10ppm alcohol) | |
Sensitivity | S | Rs(in air)/Rs(in 10ppm alcohol)≥2 | |
Concentration slope | α | ≤0.6(R 50ppm/R 10ppm alcohol) | |
Standard condition of test | Temperature, humidity | 20℃±2℃;65%±5%RH | |
Standard test circuit | VC/VH :5.0V±0.1V | ||
Warm-up time | More than 48 hours |